1. CPU module
CPU module is mainly composed of microprocessor (CPU chip) and memory. In the PLC control system, the factory CPU module is equivalent to the human brain. It continuously collects input signals, executes user programs, and refreshes the output of the system; Memory is used to store programs and data.
2. I/O module
Input module and output module are referred to as I/O module. They are the eyes, ears, hands and feet of the system and the bridge between external field devices and CPU modules.
The input module is used to receive and collect input signals, and the switch input module is used to receive slave buttons; Switch input signals from selector switch, digital dial switch, limit switch, proximity switch, photoelectric switch, pressure relay, etc; The analog input module is used to receive continuously changing analog current and voltage signals provided by potentiometers, tachogenerators and various transmitters.
The switch output module is used to control the output devices such as contactor, solenoid valve, electromagnet, indicator light, digital display device and alarm device, while the analog output module is used to control the actuator such as regulating valve and frequency converter.
The working voltage of CPU module is generally 5V, while the input/output signal voltage of PLC is generally higher, such as DC 24V and AC 220V. The spike voltage and interference noise introduced from the outside may damage the components in the CPU module or make the PLC unable to work properly. In the I/O module, optical coupler, photoelectric thyristor, small relay and other devices are used to isolate the internal circuit and external I/O circuit of PLC. In addition to transmitting signals, I/O modules also have level conversion and isolation functions.


3. Programmer
Programmers use it to generate user programs and use it to edit, check, modify and monitor the execution of user programs. The hand-held programmer cannot directly input and edit the ladder diagram, but can only input and edit the instruction list program, so it is also called the instruction programmer. It is small and cheap. It is usually used for programming small PLC or on-site debugging and maintenance.
The ladder diagram, instruction list, function block diagram and sequence function diagram program can be directly generated and edited on the computer screen by using the programming software, and the mutual conversion of different programming languages can be realized. After the program is compiled, it can be downloaded to the PLC or uploaded to the computer. The program can be saved or printed, and can also be programmed and transmitted remotely through the network.
4. Power supply
PLC generally uses 220V AC power supply or 24V DC power supply. The internal switch power supply provides DC 5V, ± 12V, 24V and other DC power supplies for each module. Small PLCs can usually provide 24V DC power for input circuits and external electronic sensors (such as proximity switches), and DC power for driving PLC loads is usually provided by users.

1B30035H01     1B30016H06     1C31224G02     1X00097H01     1D54581G03

1C31227G01     1C31203G01     1C31166G01     1X00102H01     1D54581G04

1C31169G01     1C31204G01     1C31227G02     1X00107H01     1D54582G01

1C31234G01     1C31205G01     1C31232G03     1X00126H02     1D54582G02

1C31169G02     1C31206G01     1C31233G01     1X00133H01     1D54582G03

1C31122G01     1C31107G01     1C31147G01     1X00161H01     1D54582G05

1C31125G02     1C31110G02     1C31147G02     1X00163H01     1C31192G01

1C31224G01     1C31113G01     1D42128G01     1X00163H02     1D54582G06

1C31116G04     1C31113G02     1D54416G01     1X00163H03     1C31166G02

1C31150G02     1C31113G03     1D54458G01     1X00163H04     1X00024H03

1C31132G01     1C31113G04     1D54471G02     1X00185H01     1X00093G04

1C31129G03     1C31113G05     1D54471G03     1X00377H01     1X00093G05

3A99158G01     1C31113G06     1D54540G01     1X00415H01     1X00093G06

1X00024H01     1C31116G02     1D54544G01-8     1X00416H01     1X00093G07

3A99132G02     1C31116G03     1D54557G03     1X00416H02     1X00093H08

ST24B3             1C31161G02     1D54557G07     1X00416H03     1X00093H09

5A26391H24     1C31164G02     1D54557G10     1X00416H04     1X00093G10

———————————————————-
[Disclaimer]
Our company sells new products and discontinued products, and purchases such special products through independent channels. Guizhou Yuanmiao Automation Equipment Co., Ltd. is not an authorized distributor, distributor or representative of the featured products of this website. All product names/product images, trademarks, brands and microlabels used on this website are the property of their respective owners. Product descriptions, descriptions or sales with these name images, trademarks, brands and logos are for identification purposes only and do not represent any association or authorization with any right holders.